Water & Moisture Intrusion

Water can enter a building as a liquid, a solid, as a vapor, and it can be adsorbed into most common building and finishing materials.  Basements are a high risk area for water intrusion.  Modern crawl spaces are required to have a 6 mil poly moisture barrier installed to prevent moisture from damaging floor joists an flooring etc.

 

Requirements for moisture protection for new homes with a crawl space

Water vapor can be a source of damage when it is trapped within a building assembly and cannot dry out. Warm air "carries" more water vapor than cold air. When warm air touches a cold surface, the water vapor it carries can condense, turning the vapor into its liquid form, where it can cause damage to structural components. 

Even without air leaks, small amounts of moisture in the form of water vapor can pass directly through a building’s envelope through a process called diffusion. Vapor diffusion from a damp or wet basement into the living space can significantly increase the moisture levels inside a home.

Moisture problems are frequently found in the basement of a home or building. Even in some of the driest of site conditions, foundations are continually exposed to moisture vapor from the ground. When basements are used inappropriately on sites with high groundwater, or in areas with intermittent periods of higher ground moisture levels due to rainfall and water table fluctuations, they are frequently exposed to bulk water. Therefore, foundations must be detailed to deal with the potential for water leakage through cracks and joints, capillary movement of water through foundation materials, vapor transmission of moisture through foundation materials, and condensation of moist air on cool foundation surfaces

Air Leakage vs. Diffusion 

Air leakage is the superhighway. It occurs when air moves through gaps, cracks, and holes in the building's envelope — think of unsealed joints, gaps around windows, or penetrations for pipes and wires. This moving air carries a significant amount of water vapor with it. A small, 1-square-inch hole can allow as much as 30 quarts of water to pass through a wall assembly during a single heating season.

Diffusion is the process where water vapor gradually passes directly through solid building materials, moving from an area of higher vapor pressure to an area of lower pressure. Even though materials like drywall and wood look solid, they are permeable to water vapor on a molecular level. However, the amount of moisture that moves via diffusion is incredibly small compared to air leakage.

A properly installed air barrier is essential for maintaining energy efficiency, indoor comfort, and controlling moisture movement within a home. During a home inspection, accessible areas of the building envelope are visually examined for gaps, openings, damaged materials, and poorly sealed penetrations that may allow uncontrolled air leakage. Particular attention is given to areas around windows, doors, electrical outlets, attic hatches, and plumbing penetrations. Air leakage can contribute to heat loss, drafts, condensation, and potential mould growth. While concealed air barrier components cannot be fully evaluated during a visual inspection, visible deficiencies and potential problem areas are identified and recommendations provided where appropriate.

Class of Vapour Retarders

The International Residential Code® (IRC®) defines vapor retarders based on their permeability. The ability of a material to retard the diffusion of water vapor is measured in units known as "perms" or permeability. The higher the perm rating, the more easily water vapor can pass through the material.  The IRC® describes three classes of vapor retarders, including Class I, Class II, and Class III, which are directly related to their perm ratings. 

Cold, heating-dominated climates: Place vapour retarders on the warm (interior) side of wall insulation to stop indoor moisture from condensing on cold exterior sheathing during winter. Guidance from NRC Publications and the Insulation Institute highlights how proper placement and sealing protect assemblies

Permeability chart of vapor retarders

Combination Air Barriers/Vapor Diffusion Retarders

Air barriers/vapor diffusion retarders are generally placed around the perimeter of the building just under the exterior finish, or they may actually serve as the exterior finish. The key to making them work effectively is to permanently and carefully seal all of the seams and penetrations, including around windows, doors, electrical outlets, plumbing stacks, and vent fans.

Exterior sheathing being used a combination air barrier & vapour retarder

Missed gaps of any size not only increase home energy use, but also increase the risk of moisture damage to the house, especially during the cooling season. An air barrier/vapor diffusion retarder should also be carefully inspected after installation before other work covers it. If small holes are found, they can be repaired with caulk, polyethylene or foil tape. Areas with larger holes or tears should be removed and replaced. Patches should always be large enough to cover the damage and overlap any adjacent wood framing.

Roofing Slopes

Considering several factors, a moderate roof slope (e.g., 4:12 to 7:12) provides a favorable balance of pros and cons for water-shedding systems. For example, lower roof slopes will tend to decrease drainage efficiency, allow debris to accumulate, and increase wind uplift loads on the roof.  In addition, as the roof ages or becomes damaged, leaks are very likely to be more severe. While very steep roofs will tend to increase drainage efficiency, they increase the building and roof's exposure to lateral wind loads. Furthermore, water flow velocity will be increased (particularly at valleys), which may cause scour, accelerated water, and over-shooting of gutters. Also, very steep-slope roofs are more difficult and less safe to access for construction, maintenance and replacement.  An attic designed for usable space will also introduce other considerations related to roof slope. 

Water penetration is commonly associated with flashing and detailing problems around roof penetrations, eaves, and wall intersections with a lower roof section.  Many roofers will offer discounted prices but it does not include replacing older and worn flashings.

Windows and Door Frames 

The three major window and door frame types used in conventional residential construction are wood, vinyl, and aluminum. Windows and doors can be key contributors to water penetration in walls from either flashing failures around these components or characteristics of the components themselves. This section discusses the features of window and door components that may reduce leakage and related moisture problems. Without careful installation of window and door components, it should be assumed that they will leak some amount of water into the wall cavity.  Water penetration and accumulation in walls are most commonly associated with flashing and detailing problems around windows, doors and other penetrations through the weather-resistant wall envelope.

 

Caulking and Sealants 

In the construction of the weather-resistant envelope system, there will be joints and seams that require or at least benefit from the appropriate use and maintenance of caulks and sealants. In the absence of guidelines for specification and application of caulk and sealants in model building codes, this section provides valuable information for inspectors regarding their use. Where caulk is required by a manufacturer's installation instructions, the specified caulk materials and methods should be followed carefully by the installer and then checked by the inspector.

In general, caulks and sealants should not be relied on as the primary defense against water intrusion at joints in an exterior wall covering system. Flashing is preferred wherever feasible, even when caulk is additionally used. Standard-quality caulk and application practices, combined with the shrinkage and swelling of the building's components, usually result in the onset of gradual failure of the watertight seal within a few years.

Ventilation of Attics

Ventilation of attic areas is intended to prevent the accumulation of moisture vapor in the attic/roof space and to dry low levels of condensation that may form on the underside of a roof deck. Ventilation is also intended to reduce the temperature of the roof deck during hot weather to improve shingle durability. Reducing the attic's temperature through ventilation and insulation also improves energy efficiency during hot periods. And in the case of ice dams, elevated attic and roof temperature during the winter can cause snow on the roof to melt. Insulation and roof ventilation help to keep the roof’s exterior surface cold and help minimize the development of melted water and, consequently, ice dams.

Mould on sheathing in attic from improper ventilation

Efflorescence on Basement Walls 

Efflorescence is the white chalky powder that you might find on the surface of a concrete or brick wall. It can be a cosmetic issue, or it can be an indication of moisture intrusion that could lead to major structural and indoor air quality issues. A home inspector should understand what efflorescence is in order to recognize potential moisture problems.

Indications of Moisture

Efflorescence is the dissolved salts deposited on the surface of a material (such as concrete or brick) that are visible after the evaporation of the water in which it was transported. The moisture that creates efflorescence often comes from groundwater, but rainwater can also be the source. Efflorescence alone does not pose a major problem, but it can be an indication of moisture intrusion.

Porous Building Materials

Building materials, such as concrete, wood, brick and stone, are porous materials. Porous materials can absorb or wick water by a process called the capillary action. As water moves through the porous material, salts can be drawn with it.

Concrete, wood, brick, stone and mortar are porous materials that contain salts. The ground in which these materials can come into contact also contain salts. Capillary action can literally suck water and transport it through porous building materials.

Capillary Action

Porous building materials are capable of wicking water for large distances due to capillary action with a theoretical limit of capillary rise of about 6 miles. That’s 6 miles directly up. Think of a tree and how a tree can transport water from its roots to its leaves. That’s capillary action. And it’s very powerful. When you add salt to that capillary process, it can be destructive.

Salts dissolved by groundwater can be transported by capillary action through porous soil. Building materials in contact with soil will naturally wick the water inward and upward. Take concrete footings -- they are typically poured directly onto soil without any capillary break. Sometimes this is called rising damp. This is the beginning of how water can wick upward into a structure.

Free Thermal Imaging with Every Home Inspection

Thermal imaging is included at no additional charge with every Free Thermal Imaging Scans with every Home Inspection completehome inspection. Infrared technology helps identify temperature differences that may indicate missing insulation, air leakage, moisture-related concerns or other hidden conditions. Thermal imaging complements the visual inspection and can help identify areas requiring closer examination. It is one more way we provide a thorough assessment of your prospective home.

For accurate thermal imaging readings a 20 degree difference between outside and inside temperatures is recommended.  Moisture or over heating conditions will be visible regardless of differences of temperature.

100% Money-Back Guarantee on Your Home Inspection

We stand behind our inspection services with a 100% Money-Back Guarantee. If you are not satisfied with your home inspection, you can request a refund of your inspection fee within 30 days after taking possession of your property. Our guarantee reflects our commitment to providing professional service, clear explanations and valuable information to help you make an informed purchasing decision.

Schedule Your Home Inspection Today

Whether you are purchasing a newer home, an older property or a century home in Penetanguishene, a professional inspection can help you better understand its condition. Barrie Home Inspector provides comprehensive inspections backed by extensive experience, free thermal imaging and our 100% Money-Back Guarantee. Contact us today to arrange your Penetang home inspection and receive the information you need before making your investment.

Call or Email to Book Your Home Inspection

Phone   (705) 795-8255

Email  roger@napoleon.cc

 

Roger Frost is available 7 Days a Week for your convenience.

Inspection Areas

Barrie Home Inspector